Sign in →

Test Code VBGCO Venous Blood Gas With Co-Oximetry

Performing Lab

Arnot Ogden Medical Center

Ordering Recommendations

Assessment of acid-base balance, evaluation of causes of hypoxia, and diagnosis of carbon monoxide poisoning.
Includes pH, pCO2, pO2, HCO3, tCO2, Base excess/deficit, O2Sat, Hemoglobin, Oxyhemoglobin, Methemoglobin, and Carboxyhemoglobin.

Collect

Venous Whole Blood

Collection Device

Lithium Heparin Syringe or Dark Green Top Tube.
AT IRA DAVENPORT: ONLY A HEPARINIZED SYRINGE IS ACCEPTABLE.

Specimen Volume

3 mL

Stability (from collection to initiation)

Room Temp 30 minutes

 

Storage/Transport Temperature

Room Temp

Minimum Requirements

0.5 mL

Methodology

Potentiometry, Amperometry, Spectrophotometry.

Start Date

9/13/2017

Last Review Date

7/31/2025 JLH

Specimen Handling

Room Temp

Remarks

TURN AROUND TIME

30 minutes

Notes

Send sample to Respiratory ASAP.