Test Code STFR1 sTfR (Soluble Transferrin Receptor), Serum
Ordering Guidance
This test should not be used for routine iron status evaluation for patients without confounding pathologies (such as inflammation, infection, chronic disease, or malignancy). For such cases order FERR1 / Ferritin, Serum.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL Serum
Collection Instructions:
1. Within 2 hours of collection, centrifuge the specimen.
2. For red-top tubes, aliquot serum into a plastic vial prior to sending.
Secondary ID
623578Useful For
Aiding in the diagnosis of iron deficiency anemia in patients with chronic disease
Method Name
Chemiluminescent Immunoassay
Reporting Name
Soluble Transferrin Receptor (sTfR)Specimen Type
SerumSpecimen Minimum Volume
Serum: 0.6 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Refrigerated (preferred) | 7 days |
| Frozen | 90 days | |
| Ambient | 7 days |
Reject Due To
| Gross hemolysis | Reject |
Reference Values
0.63-2.64 mg/L
It is reported that African Americans may have slightly higher values.
Cautions
The soluble transferrin receptor (sTfR) immunoassay should not be used for the routine clinical evaluation of patients for iron status when ferritin immunoassay (FERR1 / Ferritin, Serum) would be appropriate, such as in the absence of confounding pathologies (inflammation, infection, chronic disease, or malignancy).
Soluble transferrin receptor assays are not standardized, therefore results from different assays should not be used interchangeably.(3)
Patients with hemolysis and recent blood loss may have falsely elevated sTfR concentrations.
Race-based differences in sTfR have been observed with Black subjects having 9% higher values compared to non-Black subjects.(4)
Altitude-based differences in sTfR have been observed with subjects residing at high altitude having concentrations 9% higher than those nearer to sea level.(4)
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in Rochester
Test Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
84238
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| STFR1 | Soluble Transferrin Receptor (sTfR) | 30248-9 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| STFR1 | Soluble Transferrin Receptor (sTfR) | 30248-9 |