Sign in →

Test Code LAB76 Arterial Blood Gas

Performing Lab

Arnot Ogden Medical Center/ Ira Davenport Memorial Hospital

Ordering Recommendations

Used to access lung ability to take in oxygen and remove carbon dioxide, and acid/base balance of patient.

Includes pH, pCO2, pO2, HCO3, TCO2, base excess/deficit, and O2Saturation.

Collect

Arterial Whole Blood

Collection Device

Lithium Heparin Syringe

Stability (from collection to initiation)

Room Temp 30 minutes

Storage/Transport Temperature

Room Temp

Specimen Volume

2.0 mL

Minimum Requirements

1 mL

Remarks

TURN AROUND TIME

30 minutes

Methodology

Potentiometry, amperometry, spectrophotometry, ion selective electrode.

Synonyms

ABG

Start Date

9/13/2017

Last Review Date

06/24/2025

7/14/25 AP