Sign in →

Test Code LAB47 Ammonia

Performing Lab

Arnot Ogden Medical Center/ Ira Davenport Memorial Hospital

Ordering Recommendations

Assisting in the diagnosis of hepatic coma.

Investigating and monitoring treatment for inborn errors of metabolism.

Evaluating patients with advanced liver disease.

Collect

Plasma

Collection Device

Lithium Heparin Green Top Tube

Collection Instructions

Sample must be immediately placed on ice after collection. Tube must be kept closed and in a vertical position.

Sample must be tested within 30 minutes of collection.

Specimen Preparation

Patient should not clench fist. Sample must be immediately placed on ice after collection.

Stability (from collection to initiation)

Sample must be tested within 30 minutes of collection.

Storage/Transport Temperature

On Ice

Specimen Volume

5 mL

Minimum Requirements

1 mL

Remarks

TURN AROUND TIME

1 hour

Methodology

Timed Endpoint Absorbance

Start Date

9/13/2017

Last Review Date

6/19/2025

7/3/25 AP