Test Code LAB458 Cytoplasmic Neutrophil Antibodies, Serum
Reporting Name
Cytoplasmic Neutrophilic Ab, SUseful For
Evaluating patients with clinical features of ANCA-associated vasculitis, specifically granulomatosus with polyangiitis, microscopic polyangiitis, and eosinophilic granulomatosus with polyangiitis
Performing Laboratory

Specimen Type
SerumAdditional Testing Requirements
When used for diagnosis, it is recommended that specific tests for proteinase 3 antibodies and myeloperoxidase antibodies be performed first, with additional testing for anti-neutrophil cytoplasmic antibodies only needed in certain circumstances.(3) A testing algorithm based on these recommendations is available. For more information see VASC / Antineutrophil Cytoplasmic Antibodies Vasculitis Panel, Serum.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.8 mL
Collection Instructions: Centrifuge and aliquot serum into plastic vial.
Specimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Serum | Refrigerated (preferred) | 21 days |
Frozen | 21 days |
Reference Values
<1:4 (Negative)
Day(s) Performed
Monday through Saturday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86036 x2
86037-Titer (if appropriate)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
ANCA | Cytoplasmic Neutrophilic Ab, S | 87427-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
3114 | c-ANCA | In Process |
3119 | p-ANCA | 17357-5 |
Cautions
A positive result for proteinase 3 (PR3)- anti-neutrophil cytoplasmic antibody (ANCA), myeloperoxidase (MPO)-ANCA, or ANCA by IIF is not diagnostic for any ANCA-associated vasculitis and must be interpreted in the clinical context of the patient.
Negative results for PR3-ANCA, MPO-ANCA, and ANCA by indirect immunofluorescence (IIF) do not exclude the possibility of ANCA-associated vasculitis.
For monitoring disease activity, suggest ordering PR3 / Proteinase 3 Antibodies, Serum or MPO / Myeloperoxidase Antibodies, IgG, Serum
Antibodies specific for antigens other than PR3 and MPO may lead to nuclear, perinuclear or cytoplasmic staining on ethanol-fixed neutrophils. A positive or indeterminate pANCA or cANCA by IIF in the absence of a detectable PR3-ANCA or MPO-ANCA by antigen-specific immunoassay may indicate the presence of an antibody of unidentified specificity.
If ordered as a stand-alone test, all positive ANCA by IIF results should be confirmed for PR3-ANCA MPO-ANCA by solid-phase immunoassays.
Report Available
3 to 4 daysReject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | OK |
Heat-treated specimen | Reject |
NY State Approved
YesMethod Name
Indirect Immunofluorescence (IIF)
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-General Request (T239)
-Renal Diagnostics Test Request (T830)
Secondary ID
9441Testing Algorithm
For more information see:
-First-Line Screening for Autoimmune Liver Disease Algorithm.