Test Code LAB396 Urine Glucose, 24 Hour
Performing Lab
Arnot Ogden Medical Center
Ordering Recommendations
Limited usefulness in the screening or management of diabetes mellitus.
Collect
Urine
Collection Device
24 Hour Collection Jug Free of Preservatives
Specimen Volume
5 mL
Stability (from collection to initiation)
Refrigerated | 2 Hours |
Storage/Transport Temperature
Refrigerated
Minimum Requirements
1 mL
Methodology
Hexokinase G-6-PDH
Start Date
5/2/2020
Last Review Date
7/12/25 ES
Specimen Handling
Refrigerated
Collection Instructions
See Collection Instructions - 24 Hour Urine.
24 hour urine collection, keep refrigerated during collection period.
Remarks
TURN AROUND TIME
8 Hours
Specimen Preparation
Tech will enter 24 hour urine volume.
Invert well before taking aliquot.