Sign in →

Test Code LAB34 Salicylate Level

Performing Lab

Arnot Ogden Medical Center/ Ira Davenport Memorial Hospital

Ordering Recommendations

Assessing toxicity.

Collect

Serum or Plasma

Collection Device

Gold Top Tube or Lithium Heparin Green Top Tube

Collection Instructions

Sampling Time:  Peak level obtained in 1 to 2 hours, trough sample just before next dose. Serum levels drawn less than 6 hours after a toxic dose can be used to confirm overdose.

Samples should be centrifuged within 2 hours of collection.

Stability (from collection to initiation)

Room Temp 8 Hours
Refrigerated 48 Hours
Frozen Undetermined

Storage/Transport Temperature

Refrigerated

Specimen Volume

5 mL

Minimum Requirements

1 mL

Remarks

Turn Around Time

STAT 1 Hour
Routine 8 Hours

Methodology

Homogeneous enzyme immunoassay

Start Date

9/13/2017

Last Review Date

7/11/25 AP