Sign in →

Test Code LAB164 Glucose Tolerance Test, 3 hours

Performing Lab

Arnot Ogden Medical Center/ Ira Davenport Memorial Hospital

Ordering Recommendations

Diagnosing and managing diabetes mellitus and other carbohydrate metabolism disorders including gestational diabetes.

Collect

Serum or Plasma

Collection Instructions

Draw fasting glucose level and 1 hour, 2 hour & 3 hour post 100 gram glucose load.

Collection Device

Lithium Heparin Green Top Tube or Gold Top Tube

Stability (from collection to initiation)

Room Temp

8 Hours
Refrigerated 48 Hours

Storage/Transport Temperature

Room Temp or Refrigerated

Specimen Volume

5 mL

Minimum Requirements

1 mL

Remarks

TURN AROUND TIME

STAT 1 Hour
Routine

8 Hours

Methodology

Oxygen Consumption Rate

Start Date

9/13/2017

Last Review Date

06/24/2025