Test Code LAB150 C-Reactive Protein, High Sensitivity
Performing Lab
Arnot Ogden Medical Center
Ordering Recommendations
Assessment of risk of developing myocardial infarction in patients presenting with acute coronary syndromes.
Assessment of risk of developing cardiovascular disease or ischemic events in individuals who do not manifest disease at present.
Collect
Serum
Collection Device
Gold Top Tube
Specimen Volume
5 mL
Stability (from collection to initiation)
Room Temp | 11 Days |
Refrigerated | 2 Months |
Frozen | 3 Months |
Storage/Transport Temperature
Room Temp, Refrigerated, Frozen
Minimum Requirements
1 mL
Specimen Handling
Centrifuge within 2 hours of collection.
Methodology
Turbidimetry
Remarks
TURN AROUND TIME
STAT | 1 Hour |
Routine | 8 Hours |
Synonyms
C-Reactive Protein, Cardio
Start Date
5/6/20
Last Review Date
7/16/25 ES